Return to home page
Searching: Muskingum library catalog
Some OPAL libraries remain closed or are operating at reduced service levels. Materials from those libraries may not be requestable; requested items may take longer to arrive. Note that pickup procedures may differ between libraries. Please contact your library for new procedures, specific requests, or other assistance.
  Previous Record Previous Item Next Item Next Record
  Reviews, Summaries, etc...
EBOOK
Conference Keio International Symposium for Life Sciences and Medicine (13th : 2003 : Keio Gijuku Daigaku)
Title Artificial oxygen carrier : its front line / K. Kobayashi, E. Tsuchida, H. Horinouchi (eds.).
Imprint Tokyo ; New York : Springer, 2005.

LOCATION CALL # STATUS MESSAGE
 OHIOLINK SPRINGER EBOOKS    ONLINE  
View online
LOCATION CALL # STATUS MESSAGE
 OHIOLINK SPRINGER EBOOKS    ONLINE  
View online
Conference Keio International Symposium for Life Sciences and Medicine (13th : 2003 : Keio Gijuku Daigaku)
Series Keio University international symposia for life sciences and medicine ; v. 12
Keio University international symposia for life sciences and medicine ; v. 12.
Subject Blood substitutes -- Congresses.
Fluorocarbons.
Hemoglobins.
Oxygen.
Blood Substitutes -- chemistry.
Blood Substitutes -- metabolism.
Blood Substitutes -- therapeutic use.
Blood Substitutes.
Oxygen -- metabolism.
Fluorocarbons -- metabolism.
Hemoglobins -- metabolism.
Alt Name Kobayashi, K. (Koichi)
Tsuchida, E. (Eishun), 1930-
Horinouchi, H. (Hirohisa)
Description 1 online resource (xv, 280 pages) : illustrations, portrait (some color).
Bibliography Note Includes bibliographical references and index.
Contents Safety and efficacy of hemoglobin-vesicles and albumin-hemes / K. Kobayashi, H. Horinouchi, M. Watanabe, Y. Izumi, Y. Teramura, A. Nakagawa, Y. Huang, K. Sou, H. Sakai, T. Komatsu, S. Takeoka, and E. Tsuchida -- Red blood cell substitutes : past, present, and future / T.M.S. Chang -- Inhaled nitric oxide : update 2003 / W.M. Zapol -- The role of p50 in tissue oxygen delivery by cell-free oxygen carriers / R.M. Winslow -- Repetitive administration of hemoglobin raffimer in experimental models and clinical applications / H.W. Kim, G. Biro, and A.G. Greenburg -- Oxygen gradients in vivo seen by a high oxygen affinity HB polymer / E. Bucci and R.C. Koehler -- Oxygen partition between microvessels and tissue : significance for the design of blood substitutes / A.G. Tsai, B. Friesenecker, and M. Intaglietta -- Endothelial cell response to hemoglobin based oxygen carriers. Is the attenuation of pathological reactions possible? / J. Simoni -- The development of a second-generation, designer, recombinant hemoglobin / K.E. Burhop -- Hemoglobin-vesicles (HbV) as artificial oxygen carriers / H. Sakai, K. Sou, S. Takeoka, K. Kobayashi, and E. Tsuchida -- Successful ex vivo normothermic liver perfusion with purely artificial products using artificial blood / T. Katsuramaki, A. Nui, H. Kikuchi, K. Kukita, M. Nagayama, M. Meguro, H. Kimura, M. Isobe, and K. Hirata -- Effect of hemoglobin-based blood substitutes on nitric oxide transport : mathematical models / A.S. Popel, M. Kavdia, and N.M. Tsoukias -- New strategy for the preparation of NO-treated red blood cells as a blood substitute / A. Tsuneshige and T. Yonetani -- Oxygen-carrying plasma hemoprotein including synthetic heme / T. Komatsu and E. Tsuchida -- Micromechanical properties of newly developed polyelectrolyte microcapsules (PEMC) / H. Baumler, C. Kelemen, R. Mitlohner, R. Georgieva, A. Krabi, S. Schaling, G. Artmann, and H. Kiesewetter -- Intravascular microbubbles : an ultra-effective means of transporting oxygen / C.E.G. Lundgren, G.W. Bergoe, and I.M. Tyssebotn -- Oxygen-dependent and oxygen-independent effects of perftoran / E. Maevsky and G. Ivanitsky -- State of the art and challenges in blood substitutes research : a case study on perfluorocarbon-based oxygen carriers / J.C. Briceno -- Semifluorinated alkanes as stabilizing agents of fluorocarbon emulsions / S.M. Bertilla, P. Marie, and M.P. Krafft -- Possible role of artificial oxygen carriers in shock and trauma / B.T. Kjellstrom -- Clinical needs for artificial oxygen carriers in anaesthesia / R.G. Hahn -- Studies on red cell substitutes in Japan and future perspectives / M. Takaori.
Summary While a reliable supply of donated blood is vital in modern medicine, it remains the case that blood transfusion comes with its own problems, such as infectious diseases, immunological adverse reactions, and difficulties with long-term storage and transportation of blood components. With a view to solving these problems, developing a suitable blood substitute has been a major goal for decades. Artificial Oxygen Carrier: Its Front Line is a compilation of reports on the concepts behind artificial oxygen carriers, as well as the new discoveries in the field that were presented during the 13th Keio.
Note Print version record.
ISBN 4431220747 (alk. paper)
9784431220749 (alk. paper)
4431266518 (electronic bk.)
9784431266518 (electronic bk.)
ISBN/ISSN 9786610608935
OCLC # 68001127
Additional Format Print version: Keio International Symposium for Life Sciences and Medicine (13th : 2003 : Keio Gijuku Daigaku). Artificial oxygen carrier. Tokyo ; New York : Springer, 2005 4431220747 (DLC) 2004111703 (OCoLC)58843382


If you experience difficulty accessing or navigating this content, please contact the OPAL Support Team